Compliant Wet Pour On To New Base (15mm & 20mm)
RECOMMENDED STANDARD BASE DETAILS - 'WEARING COURSE' 15mm & 20mm DEPTHS ONLY
New Base Construction (assuming reasonable draining sub-soil)
- Excavate existing concrete/tarmac/grass base to a minimum of 155mm for the macadam base, or 215mm for a no fines concrete base.
- Standard edge detail is to supply and install well haunced 50mm x 150mm precast concrete edgings. Alternatives available include pressure treated timber of a minimum size of 25mm x 150mm, firmly fixed with suitable pegs at 1 metre centres.
- Supply and lay 100mm depth of M.O.T. Type 1 foundation stone.
- Supply and lay either 40mm consolidated depth of 6mm open textured macadam or 100mm depth of no fines concrete which must be flattened with a vibrating roller to create the levelest possible porous surface. Care must be taken to ensure that a consistent 15mm or 20mm depth for COMPLIANT WET POUR remains, particularly at the edges, and that the selected material is flush right up to the kerbing. Levels should be to a tolerance under a 3 metre straight edge not greater than 10mm.
- Remove all spoil material from site. Clean up, leaving site neat and tidy, reinstating where necessary.
- After a suitable period for weathering and curing has elapsed the base is ready to accept our COMPLIANT WET POUR Impact Absorbing Surfacing.
ALTERNATIVE CONCRETE BASE - 'WEARING COURSE' 15mm or 20mm DEPTH ONLY
New Base Construction (assuming reasonable draining sub-soil)
- Excavate existing concrete/tarmac/grass base to a minimum of 100mm depth of M.O.T. Type 1, selected thickness of concrete plus minimum 15mm or 20mm depth of COMPLIANT WET POUR.
- Standard edge detail is to supply and install well haunced 50mm x 150mm precast concrete edgings. Alternatives available include pressure treated timber of a minimum size of 25mm x 150mm, firmly fixed with suitable pegs at 1 metre centres.
- Supply and lay 100mm depth of M.O.T. Type 1 foundation stone.
- To ensure drainage through to base, the finished concrete should either be drilled through with 19mm / 25mm diameter holes at between 500mm or 1 metre centres or similar dimensioned conduit type piping can be set into the concrete to ensure that vertical drainage can be achieved. Holes should be back filled with a clean stone, aggregate or sand.
- Supply and lay 75mm - 100mm depth concrete with either a lightly brushed or trowelled finish. The base should be left to suitably cure before COMPLIANT WET POUR is installed.
- After a suitable curing period, if necessary, the base should be cleaned either chemically or with a power hose / pressure cleaner to remove any dirt and debris.
- If necessary the base should be suitably primed to accept COMPLIANT WET POUR.
- Base is now ready to accept COMPLIANT WET POUR Impact Absorbing Surfacing.
- Reinstate where necessary, if and as agreed.
- Remove all spoil material from site, clean up, leaving site neat and tidy.
|
< Return to Compliant Wet Pour Downloads
|